onan 10k generator

Onan Cummins generator Service Manual - iRV2 Forums- onan 10k generator ,2013224·Location: Austin, Texas. Posts: 413. Onan Cummins generator Service Manual. I have the HDKCA - 10,000k diesel generator in my RV. I had the SERVICE manual URL bookmarked, went to the bookmark last night, and it was no longer there. Went to the Onan website and they only have the spec sheet and owners manual online. You …How to Fix Fault Code 37 on Onan Generator? (Error Solved!)To solve the fault code 37 on Onan generator, just check and follow the steps below: – Step #1: Check Summer/Winter Setting – Step #2: Check Regulator for Altitude – Step #3: Check Propane Bottle – Step #4: Check Spark Plug Gap. Some of the potential problems you will not be able to fix by yourself, as they require some specialized ...



Onan Fault Code 13 - iRV2 Forums

20181027·We stored the coach for 1 1/2 months. While driving to the campground last week, I ran it with the A/Cs to exercise the unit. After about 5 miles, the generator shut down. When we arrived at the campground, I made sure the A/Cs were off, and started the generator. It ran for 4 seconds and shut down, with a fault code 13 - “under voltage”.

Onan 12500 - Where is the Fan Belt? - iRV2 Forums

201974·The fan belt was "rolled" onto the pulleys. Alternator belt = 40-41" ID X 1/2". Fan belt = 30-30 1/2" ID X 1/2" (NAPA A30 was used). Belts were badly frayed at 1000 hours (On a car this would probably be 40-50k miles). This is a difficult job and takes 8-10 hours (Including cleaning of fan and baffle).

Onan 10K Fuel Filter Replacment Hours - iRV2 Forums

201888·My owner's manual (attached) shows oil & oil filter change for a 2007 Onan Quiet Diesel 10,000 watt generator to be 250 hours (or at least once per year). The 500 hour timing to change air and fuel filters is the same for all Onan Quiet Diesel generators per the manual (see page 23). Hope this info helps!

How to change Onan QD 10000 Fuel Filter? - iRV2 Forums

201641·There is!! Onan left us a lot of extra hose for a reason. 1. Remove the center nut that holds the filter to the bracket. A standard ratchet works fine for this. 2. After the nut is removed, Push the filter toward the rear of the generator about 2-3 inches.

RV Generator Manuals | Cummins Inc.

Onan RV Generators; Parts and Maintenance; RV Generator Electricity Basics; Wireless RV Generator Start System

Cummins Onan QD 10000 RV Diesel Generator - Absolute …

Cummins Onan QD 10000 RV Diesel Generator - 10.0HDKCA-11506, 10 kW Prime, Single-Phase, 120/240 Volt, Liquid-cooled. Easy maintenance with single-side service. …

Cummins Onan 10000 Watt Generators - Electric Generators Direct

Onan 10000 Watt superstore. Huge selection of Onan 10000 Watt Generators. Buy Onan 10000w Generator Direct and save.

Onan QD 10K Won't crank - Solved - iRV2 Forums

2022629·On the Onan 10000 & 12500 generators, the circuit board (also known as the control board) is a sealed part - see attached photos. There are three relays located close by, but they're not part of the control board. ... I have a 2009 Scepter with a 10k Onan generator that won't start.It has a code 32(se: DaveyD1: Monaco Owner's Forum: 3: 08 …

Onan generator runs then stops - iRV2 Forums

2020628·Onan generator runs then stops. Mission Statement: Supporting thoughtful exchange of knowledge, values and experience among RV enthusiasts. We have an Onan Quiet Diesel 10000 (10HDKCA) that will run for a while and then shut off. Sometimes it will run for an hour, sometimes only 15 or 20 minutes, and sometimes it will …

Onan Generator Life Expectancy - iRV2 Forums

2010331·Running it under load helps keep moisture out of the generator coils. 6,500 hours sounds like a lot of use, but it probably isn't bad for a diesel. For comparison, if you averaged 40 miles per hour in the motorhome, you would drive 260,000 miles in 6,500 hours. 03-30-2010, 06:42 AM. Wizard.

Onan 12.5kw generator belts - iRV2 Forums

2021718·Our previous motorhome – a 2010 Tiffin Allegro Bus – had an Onan 10K diesel generator. That generator had only one belt, located at the back end of the generator, which drove the water pump. The original belt was Onan part number 0511-0219 which cross-referenced to a NAPA A29 industrial belt.

Topic: Onan Generator Cranking Amps - Good Sam Enterprises

2019910·What is the expected cranking amp draw for a Onan 10K generator? ... As shown in the picture below, my generator (Onan 10 KW QuietDeisel) has a dedicated battery that is only used to start the generator. The 12V+ lead is 4/0 wire 72" long. The ground wire is 48" connected to the frame.

Onan 10.0K Diesel Generator Control Board? - iRV2 Forums

2016418·The generator on our coach did the same thing, it's 12.5KW Onan. Initially, I just hot-wired the fuel pump to +12VDC using an in-line fuse that I would install when we needed the generator. Worked flawlessly, but it was a bit cumbersome and my wife was reluctant to learn the "new" generator operating sequence.

Commercial Mobile Generator - Cummins

Generator ONAN QD 10000 Features and Benefits Weight, Size and Sound Level Computer-controlled constant speed operation Unique sound-controlled housing …

How to Read Onan Generator Fault Codes (Cummins Blink Code)

Code 2 - Low Oil Pressure. This code will only blink twice. It shows that the generator is low on oil and you need to add more. Twist off the yellow cap to look at the gauge and see how much more you need to put in.

Oil Type: What Oil Does my Onan Generator Use?

The best oil you can use for your new Onan generator would be a SAE 30W viscosity oil. At best you would probably need to use 1.6 quarts to fill the oil tank. To get all the facts about maintaining your Onan generator just continue to read our article. The facts help make your Onan generator last along time. Onan Oil Type 101.

Topic: Onan 10K QD Code 45- Speed sense fault issue - RV

The service manual code 45 has the following diagnosis. 1- Service the brushes and slip rings as necessary. and test the generator field and quadrature windings for open shorts. replace a rotor or stator with faulty windings (the quadrature windings provide the speed sense signal. 2- replace controller.

onan 10k generator for sale | eBay

Find great deals on eBay for onan 10k generator. Shop with confidence.

981-0277 I4 HDKCA/B - RV Tech Library

RV Generator Set HDKCA Spec A−C HDKCB Spec A−C English 12−2008 981−0277 (Issue 4) The following symbols are used in Onan manuals to alert users to the potentially dangerous condi-tions relating to maintenance of equipment and re-placement of parts. Please read and observe. This symbol warns of immedi-

Cummins Onan RV QD10000 - 10HDKCA11506 - 10kW RV …

201138·Buy Cummins Onan RV QD 10000 Direct. Free Shipping. Check the Cummins Onan RV QD10000 - 10HDKCA11506 - 10kW RV Generator (Diesel) ratings …

Onan 10k diesel Cranks but will not start ...Help - iRV2 Forums

2017116·Originally Posted by RobRoy. Onan 10k Generator cranks over but will not start and run or even attempt to fire a cylinder for that matter. It has been running fine has about 400 hours on it and had a full service in it 3 months ago and was ran as recently as two weeks ago and started and ran just fine. Coach has ¾ Fuel tank of fuel and the ...

RV Generator Handbook - cdn.ltvdns

spec and serial number of your Cummins Onan RV generator. These numbers are printed on your Cummins Onan generator unit nameplate. Write them in below for easy reference. Model No: Serial No: Since the 2008 model year, Cummins Onan RV generator models have had new model names, to more closely align them with the Cummins model …

Bell End Bearing Replacement - Onan 10K Generator - iRV2

2017313·Onan 10k generator block heater: redbaron73: Newmar Owner's Forum: 5: 12-19-2012 09:55 AM: Onan 10K Diesel Generator: al_mers: MH-General Discussions & Problems: 7: 02-26-2010 10:49 AM » Recent Discussions: Grey water tank fittings. 1998 Dutch Star Grey water tank... drivers side dash opening.

New and used Onan RV Generators for sale - Facebook

Onan 6.5 RV Generator. Alamosa, CO. $275. Sportsmen Dual Fuel RV Generator. Littleton, CO. $10,495. Cummins Onan QD 10000 10kW RV Generator 10HDKCA11506 RV Diesel Single Phase 120 Volt New. Detroit Lakes, MN.

Onan QD 10000 | Cummins Inc.

Features & Benefits. Specifications. Ratings & Spec Sheets. Computer-controlled constant speed operation - quiet diesel performance for larger RVs. Special sound-controlling housing encloses cooling system and …

Cummins Onan 10000 Watt Generators - Electric Generators …

View Details. Compare. Cummins Onan QD 10000 - 10HDKCC42345 - 10,000 Watt Quiet Diesel Commercial Mobile Generator (120/240V 45A) Model: A055E848. Write A Review. Q&A (1)